This course is intended for
The primary audience for this course is any IT, facilities or data centre professional, consultant and/or those who work in network cabling system design, implementation and operation.
Overview
With few exceptions, enterprises today rely on IT for the delivery of business-critical services - often directly to the end consumer.
It is therefore vital that the mission-critical data centre is designed, maintained and operated with high-availability and efficiency in mind. Among all the facilities, network cabling is the foundation for the network and one of the major contributors to the availability of the data center.CNCDP© is a 2-day course designed to expose participants to in-depth knowledge in designing and installing the data network cabling system which includes key subject matters such as; technical standards, designing of different cabling sub-systems, calculation of material requirements, architecture, installation, testing and acceptance.
Introduction to Structured Cabling System (SCS)
Brief history of SCS
Basic copper and fibre transmission
Copper and fibre cabling
Single and multimode fibre
Step/graded index multimode fibre
Difference between Commercial Wiring and data centre cabling
Development of standards
Role of standards
ANSI/TIA 568 standard
Common standards
The new usage of cabling to support Smart building
Horizontal and Administration - Commercial Building
Standard diagram recap: ANSI/TIA-568
Functional elements and example
Scenario A: Determine the number of work areas
Scenario B: Determine the number of user locations
Zone wiring
Administration: Interconnect and cross-connect
Angled and flat panels
Creating a cabling schematic design
Convert schematic into physical layout
Calculating the material list
Horizontal and Administration - Data Centre
Standard diagram recap: TIA-942
Basic/Reduced/Typical data centre setup
Traditional 3 layers network design/ Spine and Leaf network design
Select termination hardware
Administration design
ToR/EoR/Spine & Leaf cabling design
Network and cabling resiliency
Create cabling schematic design for ToR/EoR
Convert into patch panel/rack layout
Calculate the material list for ToR/EoR
Building Backbone - Commercial Building
Backbone diagram
Calculate the copper backbone requirements per Telecom Room (TR)
Calculate the fibre backbone requirements per Telecom Room
Summarize the building backbone requirements
Recognised cables
Backbone Patch panels
The maximum backbone distances
Create cabling schematic design
Converting the schematic design into patch panel/ rack layout
Building Backbone - Data Centre
TIA-942 based backbone topology
TIA-942 backbone requirements
Recognised backbone cable
ToR/EoR/Spine and Leaf
Backbone distance estimation
Resiliency of backbone cable routes
Creating cabling schematic design
Converting the schematic design into patch panel/ rack layout
Field and Fusion Termination for fibre connectors
Pre-terminated fibre trunk and copper cables
Architectural Considerations
ANSI/TIA569-D Cable pathway and spaces
Common requirements for the rooms
Definition of the rooms
Entrance Room/Demarcation
Ceiling and floor pathways types
Cable trays/basket/ladder/conduit
Inner duct/sleeve/slot
Calculating of pathway size
Cable run best practices
Cable management/AIM
Grounding and bonding
Separation distance requirements for copper cabling to power cabling
Fire stopping
Fire rated barrier
Fire rated jacket cable
Campus / Outdoor Backbone
Common campus cable installation and cable types : Aerial cable / Direct-buried / Underground in-conduit
Outdoor cable installation planning
Lightning / surge protection
Approved ground for surge protector
Creating a schematic diagram
Converting a schematic into a physical layout
Site Inspection and Testing
Visual site inspection notes
Installation common issues
Copper testing standard
Permanent link / Channel / Patch cord / MPTL testing configuration
Fibre connectors
Fibre testing standard
Tier 1 & 2 certification
Fibre link definition
Fibre testing steps
Fibre inspection and cleaning
Calibrating the test sets - 3 methods
Setting up mandrel for testing
Fibre loss budget calculation
G.657 Bend insensitive fibre
Optical Time-Domain Reflectometer (OTDR)
Exam - Certified Network Cabling Design Professional (CNCDP©)
The exam is a 60-minute closed book exam, with 40 multiple-choice questions.
The candidate requires a minimum of 27 correct answers to pass the exam.
Additional course details:
Nexus Humans Certified Network Cabling Design Professional (CNCDP) training program is a workshop that presents an invigorating mix of sessions, lessons, and masterclasses meticulously crafted to propel your learning expedition forward.
This immersive bootcamp-style experience boasts interactive lectures, hands-on labs, and collaborative hackathons, all strategically designed to fortify fundamental concepts.
Guided by seasoned coaches, each session offers priceless insights and practical skills crucial for honing your expertise. Whether you're stepping into the realm of professional skills or a seasoned professional, this comprehensive course ensures you're equipped with the knowledge and prowess necessary for success.
While we feel this is the best course for the Certified Network Cabling Design Professional (CNCDP) course and one of our Top 10 we encourage you to read the course outline to make sure it is the right content for you.
Additionally, private sessions, closed classes or dedicated events are available both live online and at our training centres in Dublin and London, as well as at your offices anywhere in the UK, Ireland or across EMEA.
Nexus Human, established over 20 years ago, stands as a pillar of excellence in the realm of IT and Business Skills Training and education in Ireland and the UK....