• Professional Development
  • Medicine & Nursing
  • Arts & Crafts
  • Health & Wellbeing
  • Personal Development

253 Courses in Manchester delivered On Demand

PV201L: Solar Training - Solar Electric Lab Week (Grid-Direct)

By Solar Energy International (SEI)

Students who complete the PV201L workshop will be able to: Perform power and energy calculations Obtain and apply specifications for PV modules and determine their performance given various environmental and operating conditions Safely operate various types of digital multimeters Diagram and determine the power, current, and voltage characteristics of PV modules in different series and parallel configurations Install various mounting systems (ground, pole, roof, and trackers). Decipher balance-of-system equipment specification sheets to determine the critical information needed for system design Install a residential grid-direct system including the array, inverter, circuit conductors, and overcurrent protection Safely operate equipment grounding, system grounding, and components and conductors used for grounding Work with wires and components on schematics of residential grid-direct systems: disconnects, inverter, equipment grounding conductors, ungrounded conductors, grounded conductors, the grounding electrode(s), and the AC and DC system grounds Identify potential safety hazards and demonstrate the proper use of personal protective equipment for working on grid-direct PV systems List the order of installation, commissioning, and decommissioning of a grid-direct PV system Note: This class is a great complement to PV301L, the Solar Electric Lab Week (Battery-Based).

PV201L: Solar Training - Solar Electric Lab Week (Grid-Direct)
Delivered Online On Demand
£1,255.73

PV201LW: Solar Training - Women's Solar Electric Lab Week (Grid-Direct)

By Solar Energy International (SEI)

Students who complete the PV201L workshop will be able to: Perform power and energy calculations Obtain and apply specifications for PV modules and determine their performance given various environmental and operating conditions Safely operate various types of digital multimeters Diagram and determine the power, current, and voltage characteristics of PV modules in different series and parallel configurations Install various mounting systems (ground, pole, roof, and trackers). Decipher balance-of-system equipment specification sheets to determine the critical information needed for system design Install a residential grid-direct system including the array, inverter, circuit conductors, and overcurrent protection Safely operate equipment grounding, system grounding, and components and conductors used for grounding Work with wires and components on schematics of residential grid-direct systems: disconnects, inverter, equipment grounding conductors, ungrounded conductors, grounded conductors, the grounding electrode(s), and the AC and DC system grounds Identify potential safety hazards and demonstrate the proper use of personal protective equipment for working on grid-direct PV systems List the order of installation, commissioning, and decommissioning of a grid-direct PV system Note: This class is a great complement to PV301L, the Solar Electric Lab Week (Battery-Based). This Women's Solar Electric Lab Week is powered by:

PV201LW: Solar Training - Women's Solar Electric Lab Week (Grid-Direct)
Delivered Online On Demand
£1,255.73

Grounding, Clearing and Protecting

By Neil Christey - The Holistic College

Syllabus: Holistic Protection and Energetic Practices Course Overview This course introduces essential spiritual practices for grounding, protection, and clearing. These skills create a foundation for personal and energetic stability, enhancing focus, clarity, and resilience. Through visualisation, meditation, and energy exercises, students will develop a profound understanding of grounding techniques, protective boundaries, and clearing practices.  Module 1: Grounding - Core Techniques: Visualise roots or boulders for grounding; use the tree visualisation for strength. - Daily Application: Practical tips for staying present and connected. - Reflection: Journaling prompts to track emotional and physical responses. Module 2: Protection - Creating Boundaries: Use protective visualisations like light shields and cloaks. - Protective Tools: Elemental circles, crystals (e.g., black tourmaline), and symbols (Ankh, Eye of Horus). - Invocation Practices: Call upon Archangels and guides for energetic support. - Reflection: Journaling to observe the effects of protection techniques. Module 3: Clearing - Clearing Practices: Techniques for personal and environmental energy clearing. - Crystal Grids: Setup for maintaining energetic cleanliness. - Advanced Visualisations: Use the violet flame for thorough cleansing. - Reflection: Journaling on the experience of clearing exercises.

Grounding, Clearing and Protecting
Delivered Online On Demand3 hours
£19.99

PV202: Solar Training - Advanced PV System Design and the NEC (Grid-Direct)

By Solar Energy International (SEI)

Students who complete PV202 will be able to: Define the purpose of the National Electrical Code (NEC®) and NEC® terminology for PV equipment Determine procedures for proper installation of equipment and conductors, including minimum requirements for working space Examine methods for PV wire management and determine where expansion fittings are required Describe and identify electrical services, including split-phase and three-phase Wye (Y) and Delta (∆) Evaluate electrical service details to collect and record during solar site evaluation Identify options for NEC®-compliant PV system interconnection to the utility grid and determine whether a supply side, load side, or additional service connection is appropriate Identify code-compliant methods for connecting an inverter to an existing AC feeder Calculate PV module voltage based on temperature to ensure compatibility with system components and NEC® Section 690.7, and explore other options for maximum PV system DC voltage calculations Identify NEC® requirements and sizing of disconnects and overcurrent protection devices (OCPDs) in grid-direct PV systems Define inverter grounding configurations Evaluate inverter choices and system configurations, including string inverters, central inverters, and module level power electronics (MLPE) Identify requirements for equipment grounding, equipment grounding conductors (EGC), and grounding electrode conductors (GEC), and size the conductors according to the NEC® Identify common causes of ground-faults and arc-faults Describe ground-fault and arc-fault protection devices Describe benefits and appropriate locations of surge protection devices (SPD) Demonstrate the use of sun charts and perform calculations to determine row spacing and minimize inter-row shading Identify how Codes detailing access for first responders impact PV array roof layout Examine fire classifications that affect racking and module selection Detail NEC rapid shutdown requirements and options for implementation Identify load and structural considerations for low- and steep-slope roof-mounted PV systems Calculate wind uplift force and select appropriate lag bolts Review issues related to planning, design, and installation of ground-mount PV arrays Review PV system circuit terminology, definitions, and conductor types Calculate minimum overcurrent protection device (OCPD) size and conductor ampacity using appropriate adjustment and correction factors Calculate voltage drop and verify system operation within acceptable limits Examine requirements for PV system labeling Calculate the maximum and minimum number of modules per PV source circuit, and number of PV source circuits per inverter Determine size of residential grid-direct PV system based on site and customer-specific considerations including the number and wiring layout of modules, conductor and OCPD sizes, and the AC interconnections Determine the size of a large, multiple inverter, grid-direct PV system based on site and customer-specific considerations, including the quantity and layout of modules and inverters and the AC interconnection Define large-scale PV and review associated NEC® allowances and requirements Describe importance of Data Acquisition Systems (DAS) Identify common DAS equipment and hardware Review DAS design, installation, and commissioning processes and common problems associated with DAS Show how reports can be generated and utilized to remotely assess health of system

PV202: Solar Training - Advanced PV System Design and the NEC (Grid-Direct)
Delivered Online On Demand
£759.54

PVOL202: Solar Training - Advanced PV System Design and the NEC (Grid-Direct) - Online

By Solar Energy International (SEI)

Students who complete PVOL202 will be able to: Define the purpose of the National Electrical Code (NEC®) and NEC® terminology for PV equipment Determine procedures for proper installation of equipment and conductors, including minimum requirements for working space Examine methods for PV wire management and determine where expansion fittings are required Describe and identify electrical services, including split-phase and three-phase Wye (Y) and Delta (∆) Evaluate electrical service details to collect and record during solar site evaluation Identify options for NEC®-compliant PV system interconnection to the utility grid and determine whether a supply side, load side, or additional service connection is appropriate Identify code-compliant methods for connecting an inverter to an existing AC feeder Calculate PV module voltage based on temperature to ensure compatibility with system components and NEC® Section 690.7, and explore other options for maximum PV system DC voltage calculations Identify NEC® requirements and sizing of disconnects and overcurrent protection devices (OCPDs) in grid-direct PV systems Define inverter grounding configurations Evaluate inverter choices and system configurations, including string inverters, central inverters, and module level power electronics (MLPE) Identify requirements for equipment grounding, equipment grounding conductors (EGC), and grounding electrode conductors (GEC), and size the conductors according to the NEC® Identify common causes of ground-faults and arc-faults Describe ground-fault and arc-fault protection devices Describe benefits and appropriate locations of surge protection devices (SPD) Demonstrate the use of sun charts and perform calculations to determine row spacing and minimize inter-row shading Identify how Codes detailing access for first responders impact PV array roof layout Examine fire classifications that affect racking and module selection Detail NEC rapid shutdown requirements and options for implementation Identify load and structural considerations for low- and steep-slope roof-mounted PV systems Calculate wind uplift force and select appropriate lag bolts Review issues related to planning, design, and installation of ground-mount PV arrays Review PV system circuit terminology, definitions, and conductor types Calculate minimum overcurrent protection device (OCPD) size and conductor ampacity using appropriate adjustment and correction factors Calculate voltage drop and verify system operation within acceptable limits Examine requirements for PV system labeling Calculate the maximum and minimum number of modules per PV source circuit, and number of PV source circuits per inverter Determine size of residential grid-direct PV system based on site and customer-specific considerations including the number and wiring layout of modules, conductor and OCPD sizes, and the AC interconnections Determine the size of a large, multiple inverter, grid-direct PV system based on site and customer-specific considerations, including the quantity and layout of modules and inverters and the AC interconnection Define large-scale PV and review associated NEC® allowances and requirements Describe importance of Data Acquisition Systems (DAS) Identify common DAS equipment and hardware Review DAS design, installation, and commissioning processes and common problems associated with DAS Show how reports can be generated and utilized to remotely assess health of system

PVOL202: Solar Training - Advanced PV System Design and the NEC (Grid-Direct) - Online
Delivered Online On Demand
£683.21

PV303: Solar Training - Advanced PV Multimode and Microgrid Design (Battery-Based)

By Solar Energy International (SEI)

Multimode system configurations Load analysis and battery bank sizing PV array sizing Specifying multimode inverters Advanced multimode functions Code compliance, best practices, and installation considerations Charge controllers for multimode systems DC coupled multimode battery backup design example AC coupled system design considerations AC coupled multimode battery backup design example Energy Storage Systems (ESS) overview ESS residential sizing example Large-scale multimode system design and use cases   Note: SEI recommends working closely with a qualified person and/or taking PV 202 for more information on conductor sizing, electrical panel specification, and grounding systems. These topics will part of this course, but they are not the focus.

PV303: Solar Training - Advanced PV Multimode and Microgrid Design (Battery-Based)
Delivered Online On Demand
£759.54

PV304: Solar Training - Advanced PV Stand-alone System Design (Battery-Based)

By Solar Energy International (SEI)

Stand-alone system configurations Charge controller and array considerations RV system design example DC lighting system design example Clinic system design example Code compliance and best practices for stand-alone systems Advanced battery-based inverters Generator sizing DC coupled stand-alone residential system design example AC coupled stand-alone microgrid system design example Large-scale microgrid considerations and case studies Flooded battery maintenance considerations Stand-alone PV system commissioning and maintenance Note: SEI recommends working closely with a qualified person and/or taking PV 202 for more information on conductor sizing, electrical panel specification, and grounding systems. These topics will part of this course, but they are not the focus.

PV304: Solar Training - Advanced PV Stand-alone System Design (Battery-Based)
Delivered Online On Demand
£759.54

CE522: 2017 National Electrical Code™ and PV Systems

By Solar Energy International (SEI)

Updates to rapid shutdown requirements for PV systems on buildings. Updates to grounding requirements for PV systems. Introduction to 4 entirely new articles: Energy Storage, Stand-alone Systems, DC Microgrids, and Large-Scale PV Electric Power Production Facilities. Updates to system disconnects and associated labeling New requirements for battery-based PV systems, both stand-alone and interactive. Additional changes in Articles 690 and 705, as well as other relevant Articles.

CE522: 2017 National Electrical Code™ and PV Systems
Delivered Online On Demand
£228.24

CE510: Tips, Tools and Techniques of the Solar Industry

By Solar Energy International (SEI)

Helpful tools and products used in the solar industry Residential installation tips Commercial solar installation examples Transformerless inverter installations Grid-tie with battery backup design and installation Off-grid design considerations Load side taps Grounding Ballasted roof top system design Ground mount design Custom racking Wiring methods New technologies Battery box construction

CE510: Tips, Tools and Techniques of the Solar Industry
Delivered Online On Demand
£75.57

CE501: 2011 National Electric Code Updates for the Solar Professional

By Solar Energy International (SEI)

Solar Energy International discusses the following topics: Are you are using the best temperature data to calculate maximum system voltage? Have you reviewed new requirements for labeling, marking and routing conductors? 2011 grounding and bonding requirements have been greatly simplified! Wondering about the DC arc-fault protection devices now required? Don't forget that PV source and output fuses now require disconnects within sight! SEI instructors Brian Mehalic and Rebekah Hren also discuss the following topics: The code-making process, looking to 2014, Articles 90.1(B) and 110.3, 690.4(B) Qualified persons 690.8(B)(1) and (2) Overcurrent devices and conductor ampacity 690.13 Exception 2 - Disconnecting means - all conductors 690.31(E) DC circuits inside a building - Type MC, distance from decking, marking 705.12(A) Size limits of parallel production sources

CE501: 2011 National Electric Code Updates for the Solar Professional
Delivered Online On Demand
£113.74

Educators matching "grounding"

Show all 2
Watertrain

watertrain

Warrington,

Watertrain is the predominant provider of high-quality technical training and qualification programmes to the water sector. Watertrain has been the leading provider of apprenticeships and other qualifications to the water utility sector since 2007. Watertrain sees its role as helping employers find effective solutions to immediate training needs and longer term staff development – whether through knowledge and/or competency qualifications or bespoke training interventions. Watertrain are experts in the development of nationally accredited qualifications that have been designed and written following consultation with sector employers to ensure that the resultant qualification is fit for purpose and meets their organisational needs. In conjunction with CABWI, the water sector awarding body, Watertrain developed the Level 4 Diploma in Water Industry Operations and Management. This provides an excellent grounding for graduate entrants to the sector as well as an effective progression route for those individuals that maybe in their first line management role and need to gain more knowledge and understanding at a higher and wider level. Watertrain has also now developed, again in conjunction with CABWI and wide consultation with employers, 5 new Level 3 combined qualifications. The evidence portfolio Watertrain has designed for each qualification can also be used to generate the competency and knowledge evidence to achieve the 70% required for End Point Assessment in the Water Process Technician Apprenticeship Standard. Watertrain also has an excellent competency assessment tool that can help identify current weaknesses in the level of knowledge being applied by operational teams across your business. This assessment process provides a very effective Training Needs Analysis which then optimises budget spend and targets training interventions.

Totally Holistic Health

totally holistic health

Holistic Therapist and Yogi - helping you achieve good health though natural therapies and Yoga. Totally Holistic Health was founded by myself, Julie Elder in 2005. I specialise in providing complementary therapy services.  These include Yoga, Bowen, Cognitive Behavioural Hypnotherapy, Kinesiology,  Reflexology and Reiki.  I am based in Cheadle Hulme covering the North Cheshire and South Manchester area. I have always had an interest in Natural Health even from an early age.  After years of working in a corporate environment and seeing the stresses and strains it placed on the body, health and wellbeing I was confident that I needed a change of direction. The ideal opportunity came when my son started school.  This was when I decided to retrain as a therapist.  Within 6 weeks of starting my course I discovered I was pregnant with my daughter – who said that stress doesn’t affect fertility!! I completed the first year of my course, gave birth to my daughter in the summer and continued with the second year with baby in tow.  I still however managed to achieve a college award and distinctions in my HND in Health and Complementary Therapies.  The course gave me a fantastic grounding in all aspects of working in a therapeutic environment.  This included counselling skills; psychology; sociology; diet and nutrition; anatomy and physiology. I also became qualified  Reflexology, Aromatherapy, Swedish Massage and Indian head Massage. My knowledge and determination has never wavered.   I love learning new skills, therapies and gaining new knowledge. Since qualifying in 2005 I have become qualified as a Reiki master; Advanced Bowen practitioner; Baby Massage instructor; Kinesiologist to diploma level and also hold qualifications in Pregnancy Massage; Tibetan Acupressure Head Massage; Natural face Lift Massage and Mindfulness. I am also enhancing my lifelong love of Yoga and have trained as a Yoga Teacher to enhance the treatments I can offer you. Having recently seen the devastating mental health issues after two years of coronavirus and lockdowns I also wanted to offer a supportive service to help with this too so embarked on an amazing Cognitive Behavioural Hypnotherapy course which I completed in 2022.  I am so pleased to be able this awesome modality to my therapy arsenal. Customer service is very important to me and I try to follow up each client’s treatment. Also maintaining and updating my training regularly helps me add additional skills and knowledge to help you receive the best help and advice I can give.