About GeoShield
Since 2015 construction & design standards Internationally have begun to be restructured with the aim of eliminating all possible factors that relate to the failure of systems applied to protect against life threatening ground gas ingress into new constructions. The spearhead of these changes was in the UK with the updated version of the British Standard for Good Practice on the Testing and Verification of Protection Systems for Buildings against Hazardous Ground Gases. BS 8485:2015+A1:2019 – this superseded all previous guidance. BS 8485:2015+A1:2019 operating alongside the CIRIA 735 code of practice ‘Independent Verification & Testing Programs’ has now been harmonised by many EU Countries. GeoShield Validation, Verification & Testing programs are currently underway across Europe including projects in the United Kingdom, the Republic of Ireland, Romania, Croatia, Belgium, Turkey and as far east as the Philippines. BS 8485:2015+A1:2019 sets the codes of practice which govern the installation of membrane systems designed to protect against the ingress of Methane, Carbon Dioxide and has annexes regarding Radon & VOC’s. Dependent on the various project criteria independent inspection is now often mandatory to ensure every effort is made to minimise the risk to life. GeoShield Limited are founder members of the British Verification Council and are ISO EN 9001 and ISO EN 14001 Accredited. For projects of CS2 & above (British Standards) / Amber 2 (NHBC) an Independent Testing and Verification program is required as an integral part of the project strategy. The Verification Company is usually required to be employed prior to construction. The GeoShield Verification Package is in accordance with all insistences made by the British Verification Council including £2,000,000 PI Insurance that is specific to Verification.
Key Details
Profiles
Please note, this profile is not managed by GeoShield. The information on this profile may have been submitted by an independent community member or obtained from a public source. As a result, it may be outdated or inaccurate. Logo provided by Clearbit to help identify the profile for review purposes. Cademy is an unbiased information source and does not have any affiliation with or directly endorse this profile.
Primary Location
- 18 Champion Avenue
- Castleford
- United Kingdom
- WF10 4TE
All Locations
- 18 Champion Avenue, Castleford
- 16 Bridge Street, Belfast
- 4100 Park Approach, Leeds
- 83 Princes St, Edinburgh